Galvanized Steel Coil
Hot-dip galvanized coil from 0.1 mm with zinc coating 30 to 275 g/m2, regular or zero spangle.

Product description
Galvanized coil is carbon steel with a zinc coating applied for one purpose: to stop the base steel rusting. The zinc does this twice over. It forms a barrier that keeps water and oxygen away from the steel, and where the coating is scratched it corrodes preferentially and protects the exposed steel at the cut edge. That second mechanism is why galvanized material keeps working after the surface is damaged, and why it is chosen over paint for roofing, ducting and outdoor structures.
The single most important line in a galvanized specification is the coating weight, expressed in grams per square metre of zinc. It runs from about 30 g/m2 for light indoor work up to 275 g/m2 and beyond for external and coastal service, and it drives the service life more than any other variable. A common mistake is to order by thickness and grade and leave the coating unspecified - in that case you get whatever the mill's default is, which is often the minimum.
Grades cover the range from ordinary forming to structural. SGCC, DX51D+Z and S220GD to S280GD are commercial and structural forming grades. S350GD and G550 are higher strength, used where the sheet also carries load. Galvalume, designated GL and based on an aluminium-zinc coating rather than pure zinc, offers better heat reflection and often better cut-edge performance in roofing, at a cost premium.
Spangle is the visible crystalline pattern on the surface. Regular spangle is the standard mill appearance; small and zero spangle are for painted or visible applications where the pattern must not show through the topcoat. If the coil will be pre-painted into PPGI later, tell us, because the surface preparation and the spangle both affect how the paint adheres.
Specifications
| Product name | Hot-dip galvanized steel coil |
|---|---|
| Thickness | 0.1 mm - 5.0 mm |
| Width / Diameter | 12.7 mm - 2000 mm, slit widths available |
| Length | In coils, coil inner diameter 508 / 610 mm |
| Surface | Zinc spangle regular / small / zero, zinc coating 30 - 275 g/m2 |
| Material Grade | SGCC, SGCH, DX51D+Z, S350GD, G550, CGCC, TDC51D+Z |
| Standard | ASTM A653, EN 10346, JIS G3302, GB/T 2518, DIN 17162 |
| Technology | Hot-dip galvanized / galvalume (GL), cold rolled base |
| MOQ | 25 MT per full container, small order negotiable |
| Package | Standard seaworthy export packing |
| Delivery time | 15 - 25 days after deposit, stock sizes faster |
| Payment | Confirmed per order - T/T or L/C at sight |
| Port of loading | Qingdao Port / Tianjin Port |
| Documents | MTC EN 10204 3.1, commercial invoice, packing list, CO, B/L |
Grades and equivalent standards
| SGCC | Standard JIS G3302. Commercial quality hot-dip galvanized. General forming, panels, ducting and light structures. |
|---|---|
| SGCH | Standard JIS G3302. Higher hardness and strength than SGCC. Roofing, structural panels and load bearing profiles. |
| DX51D+Z | Standard EN 10346. Commercial quality forming grade. The most widely ordered European designation for general fabrication. |
| S220GD - S280GD | Standard EN 10346. Structural grades. Load bearing panels, purlins and profiles. |
| S350GD / G550 | Standard EN 10346 / AS 1397. High strength. High strength purlins, roofing and structural profiles. |
| CGCC / TDC51D+Z | Standards JIS G3302 / EN 10346. Coating designation variants for specific markets and customers. |
Coating weight is the main driver of service life. Values are typical for each standard; the actual heat and coating mass are certified on the mill test certificate.
Typical applications
- Roofing and wall cladding
- Corrugated and trapezoidal sheet processing
- Ducting and ventilation
- Purlins, girts and light framing
- Home appliances and enclosures
- Automotive and trailer parts
- Fencing, hoarding and gates
- Agriculture and greenhouse structures
- Cold storage and warehouse panels
- Base coil for PPGI prepainting
Zinc coating weight - how to specify
Coating weight is specified in grams per square metre of zinc, usually as a two-sided total such as Z120 or 120 g/m2. Light indoor applications may take 30 to 60 g/m2; general external work commonly uses 100 to 180 g/m2; coastal, marine and heavy industrial atmospheres push toward 200 to 275 g/m2 or more. The thicker the coating, the longer the service life, and the more the material costs.
Coating structure is quoted as 2/1 or 2/2, meaning the number of coating layers on each face. 2/1 has two layers on the top face and one on the bottom and is common for roofing and panels where only one face is exposed; 2/2 is symmetric and is used where both faces matter. If the coil is to be pre-painted, tell us, because the base surface and spangle affect paint adhesion.
Packing and loading
Coils are strapped through the eye with steel bands, edge protected and wrapped in waterproof material, and loaded eye-to-sky or eye-to-wall depending on your handling equipment. Loading is at Qingdao or Tianjin into 20 ft or 40 ft containers.
Galvanized surfaces can develop white rust if moisture is trapped in transit, so waterproof wrapping is not optional. Documents are the EN 10204 3.1 mill test certificate, invoice, packing list, certificate of origin and bill of lading.
Frequently asked questions
What zinc coating weight should I specify?
It depends on the environment and the service life you need. Light indoor applications can take 30 to 60 g/m2. General external work usually uses 100 to 180 g/m2. Coastal, marine and heavy industrial atmospheres need 200 to 275 g/m2 or more. Coating weight is the biggest single factor in how long the material lasts, and it is often left unspecified, which means you get the mill default.
What does spangle mean?
Spangle is the visible crystalline zinc pattern on the surface. Regular spangle is the standard mill appearance. Small spangle and zero spangle are for painted or visible applications where the pattern must not show through. If you plan to pre-paint the coil, tell us, because spangle and surface preparation affect paint adhesion.
What is the difference between galvanized and galvalume?
Galvanized carries a zinc coating. Galvalume, designated GL, carries an aluminium-zinc coating that reflects more heat and can perform better at cut edges in roofing, but it costs more and behaves differently in forming and welding. For most general external work hot-dip galvanized is the standard choice.
Can you supply coil for prepainting?
Yes. Base coil for PPGI is supplied with the surface and spangle condition the coating line requires. Tell us what paint system will be applied so the base specification matches it.
How do I avoid white rust on arrival?
White rust forms when moisture is trapped against the zinc surface. Coils are wrapped in waterproof material and handled to avoid condensation, and the cargo is stowed away from wet areas of the vessel. If your climate is humid, mention it at enquiry stage.
What is the minimum order quantity and delivery time?
25 MT for a full container, small orders negotiable for stock sizes. Delivery is normally 15 to 25 days after deposit. Payment is confirmed per order - T/T or irrevocable L/C at sight.
Related Products

Galvanized Steel Plate / Sheet
Galvanized steel sheet combines the strength of the base steel with the sacrificial protection of zinc....
View details →
Galvanized Steel Pipe
Welded steel pipe coated with a hot-dip or electro-galvanized zinc layer for long service life in corrosive...
View details →
Galvanized Corrugated Roofing Sheet
Lightweight, strong and quick to install. The corrugated profile increases rigidity, making it a...
View details →Request a Quote for Galvanized Steel Coil
Tell us your specification - custom sizes and grades available.
Get a Quotation
Send grade, size, quantity and destination port. You get price, lead time and packing back within 24 hours (Mon-Sat).